Floor standing air to water monobloc heat pump for heating, cooling and water heating
Technical Data | 35 | 50 | 80 | 120 | |||||||||||||||||
PERFORMANCES IN HEATING* | |||||||||||||||||||||
Capacity at A-7 / W35 (Min./Nom./Max.) | kW | 1.04 / 3.51 / 4.52 | 1.04 / 5 / 5.20 | 1.79 / 7.41 / 8.45 | 2.73 / 9.51 / 11.47 | ||||||||||||||||
COP nom at A-7 / W35 | - | 3.1 | 2.9 | 3 | 3.2 | ||||||||||||||||
Capacity at A2 / W45 (Min./Nom./Max.) | kW | 1.31 / 2.55 / 5.68 | 1.33 / 3 / 6.33 | 2.3 / 4.60 / 10.21 | 3.37 / 6.35 / 13.01 | ||||||||||||||||
COP nom at A2 / W45 | - | 3.05 | 3 | 3.15 | 3.35 | ||||||||||||||||
Capacity at A+7 / W35 (Min./Nom./Max.) | kW | 1.68 / 3.5 / 6.35 | 1.68 / 5 / 7.57 | 2.74 / 8 / 11.74 | 4.23 / 12 / 14.37 | ||||||||||||||||
COP nom at A+7 / W35 | - | 5.1 | 5 | 4.8 | 4.9 | ||||||||||||||||
Operating temperature (air) Min./Max – Heating mode | °C | -20 / 35 | -20 / 35 | -20 / 35 | -20 / 36 | ||||||||||||||||
Flow temperature (water) Min./Max – Heating mode | °C | 20 / 60 | 20 / 60 | 20 / 60 | 21 / 60 | ||||||||||||||||
PERFORMANCES IN COOLING* | |||||||||||||||||||||
Capacity at A35 / W7 (Min./Nom./Max.) | kW | 1.16 / 3.5 / 4.04 | 1.16 / 5 / 5.33 | 2.45 / 7 / 8.54 | 3.30 / 9.05 / 10.45 | ||||||||||||||||
EER nom at A35 / W7 | - | 3.4 | 2.9 | 3.1 | 3.2 | ||||||||||||||||
Capacity at A35 / W18 (Min./Nom./Max.) | kW | 2.16 / 4.08 / 6.50 | 2.16 / 4.63 / 7.86 | 3.31 / 7 / 11.73 | 4.90 / 10.74 / 15.51 | ||||||||||||||||
EER nom at A35 / W18 | - | 5.3 | 4.6 | 4.7 | 2.9 | ||||||||||||||||
PERFORMACE IN DHW** | |||||||||||||||||||||
Tapping profile | L | L | L | L | |||||||||||||||||
Setpoint temperature | °C | 53 | 53 | 52 | 51 | ||||||||||||||||
Tank capacity | l | 180 | 180 | 180 | 180 | ||||||||||||||||
Heat-up time | h:min | 01:55 | 01:31 | 01:03 | 00:55 | ||||||||||||||||
Stand-by power input (Pes) | W | 38 | 38 | 38 | 38 | ||||||||||||||||
COP | 3.1 | 3.1 | 3.1 | 3.1 | |||||||||||||||||
Water volume at 40°C | l | 233 | 233 | 233 | 233 | ||||||||||||||||
NIMBUS COMPACT NET R32 | 35 | 50 | 80 | 120 | |||||||||||||||||
ErP Energy class in heating 35°C /55 °C | A+++/A++ | A+++/A++ | A+++/A++ | A+++/A++ | |||||||||||||||||
DHW energy class | A+ | A+ | A+ | A+ | |||||||||||||||||
Tapping profile | L | L | L | L | |||||||||||||||||
CODE SINGLE PHASE | Available H2 2023 | ||||||||||||||||||||
CODE THREE PHASE | Available H2 2023 | ||||||||||||||||||||
* Data according to EN 14511 ** Data according to EN 16147 |
|||||||||||||||||||||
Technical Data | 30 | 50 | 80 | 120 | 150 | ||||||||||||||||
Voltage/frequency (1-ph) - v/ph/Hz | 230/1/50 | 230/1/50 | 230/1/50 | 230/1/50 | 230/1/50 | ||||||||||||||||
Voltage/frequency (3-ph) - v/ph/Hz | - | - | 400/3/50 | 400/3/50 | 400/3/50 | ||||||||||||||||
Sound power level internal unit - dB(A) | 35 | 35 | 35 | 35 | 35 | ||||||||||||||||
Weight - kg | 127 | 127 | 127 | 127 | 127 | ||||||||||||||||
Heating element - kW | 2+2 | 2+2 | 2+2 | 2+2+2 | 2+2+2 | ||||||||||||||||
Fittings circuit heating/DHW | 1"/ 3/4"M | 1"/ 3/4"M | 1"/ 3/4"M | 1"/ 3/4"M | 1"/ 3/4"M | ||||||||||||||||
Flow rate min/nom - l/h | 480/640 | 650/860 | 1050/1400 | 1580/2100 | 1950/2600 | ||||||||||||||||
Max absorbed power - kW | 4.1 | 4.1 | 4.1 | 6.1 | 6.1 | ||||||||||||||||
Expansion vessel capacity - L | 12 | 12 | 12 | 12 | 12 | ||||||||||||||||
Minimum water quantity - L | 17.5 | 25 | 40 | 60 | 75 |